Precision-engineered aluminum and uPVC commercial doors optimized for Turkish wind load standards (TS EN 12210), acoustic dampening, and seismic movement.
Heavy-duty thermal break profile with multi-chamber polyamides. Ideal for severe weather zones in Central Anatolia and high-end Istanbul office towers.
Send an Inquiry
Designed for heavy foot traffic in shopping complexes and hotel lobbies across Izmir and Antalya. Exceptional air permeability and water tightness.
Send an Inquiry
Structural-grade aluminum frame with tempered double safety glass. Engineered for high seismic zones (Zone 1) in Marmara industrial corridors.
Send an Inquiry
Multi-chamber European profile design providing enhanced sound insulation (Rw up to 42 dB) for urban medical facilities and educational complexes.
Send an Inquiry
Minimalist sightlines maximizing daylight penetration. Perfect for high-rise commercial facades and luxury showroom entrances in Ankara.
Send an Inquiry
Incorporates high-security multi-point locking mechanisms and low-threshold profiles compliant with barrier-free commercial access standards.
Send an Inquiry
Tested against dynamic wind pressure up to 3000 Pa. Recommended for coastal commercial developments along the Black Sea and Aegean coasts.
Send an Inquiry
Custom decorative grill integration combined with double-tempered Low-E insulated glass packages for boutique hotels and executive offices.
Send an InquiryFrom the humid coastal environments of the Mediterranean to the extreme freeze-thaw cycles of Eastern Anatolia, commercial entrances must meet distinct environmental challenges.
High-density urban corridors demand elevated acoustic isolation (Rw > 40 dB) to eliminate traffic noise and high structural load-bearing capacity for skyscraper podium entrances subject to intense stack pressures.
Severe seasonal temperature fluctuations (from -15°C winter nights to +38°C summer days) require low U-value (≤ 1.3 W/m²K) thermal break aluminum profiles to minimize interior HVAC loading and prevent frame condensation.
Severe saline marine atmospheres require Qualicoat Class 2 or anodized surface coatings (25 microns+) to guarantee zero aluminum corrosion, combined with high solar heat gain coefficient (SHGC) glass controls.
Comprehensive engineering parameters verified under European (EN) and Turkish (TS) standard testing protocols.
| System Classification | Profile Material & Thermal Break | Thermal Transmittance (Uf) | Acoustic Rating (Rw) | Air Permeability (EN 12207) | Water Tightness (EN 12208) |
|---|---|---|---|---|---|
| Heavy Commercial Entrance | Extruded T6 6063 Aluminum / 24mm PA66 | 1.2 - 1.5 W/m²K | 38 - 45 dB | Class 4 (600 Pa) | Class E1050 (1050 Pa) |
| Automatic Storefront Sliding | Thermal Aluminum / Dual EPDM Seals | 1.4 - 1.7 W/m²K | 35 - 40 dB | Class 3 (300 Pa) | Class 9A (600 Pa) |
| High-Security Fire Exit Door | Galvanized Steel Core / Thermal Intumescent | 1.6 - 1.9 W/m²K | 32 - 38 dB | Class 3 (300 Pa) | Class 7A (300 Pa) |
| Slimline Architectural Casement | High-Tensile Aluminum / 18mm Polyamide | 1.3 - 1.6 W/m²K | 40 - 44 dB | Class 4 (600 Pa) | Class E900 (900 Pa) |
Turkey’s commercial architectural landscape is experiencing a paradigm shift driven by green energy mandates, seismic resilience standards, and international hotel chain developments. Project directors, main contractors, and facade engineers across Istanbul, Ankara, and Izmir are actively replacing standard, non-insulated extrusions with high-performance thermal break assemblies to meet updated TS 825 (Thermal Insulation Requirements in Buildings) targets.
Key technical drivers shaping commercial door procurement include:
Decades of specialized manufacturing expertise, rigid quality assurance, and seamless B2B international supply chain execution.
From aluminum extrusion alloy verification (6063-T6) to automated multi-corner fusion welding, thermal break insertion, and CNC hardware routing, every single door assembly undergoes strict in-factory quality controls prior to export packaging.
We do not constrain developers to rigid catalog stock sizes. Commercial doors are custom-engineered to field-measured dimensions, catering to unique architectural entrance arches, trapezoids, and oversized structural spans.
Full documentation support including ATR, EUR.1 certificate of origin, CE declarations, and test reports. Direct containerized sea freight to key Turkish ports: Ambarlı (Istanbul), Gemlik, Mersin, and Alsancak (Izmir).
Direct answers for project managers, architectural specifiers, and trade importers.
Our commercial door systems strictly comply with European Norms (EN 14351-1) and carry valid CE marking required for customs entry into Turkey. The thermal break profiles meet the thermal resistance calculations outlined in TS 825, achieving system U-values as low as 1.1 W/m²K depending on the selected Low-E argon glass configuration.
We provide comprehensive export packing (heavy-duty wooden crate protection with desiccants and protective film) and issue complete shipping dossiers including Commercial Invoices, Packing Lists, Bills of Lading, CE Compliance Certificates, and ATR/EUR.1 origin documentation to streamline customs clearance at Ambarlı, Mersin, or Izmir ports.
Yes. We supply specialized commercial egress doors tested under EN 1634-1 fire resistance standards (E30, E60, E90 ratings) equipped with European-certified panic hardware (EN 1125), auto-drop acoustic bottom seals, and electromagnetic hold-open door closers.
Our standard production lead time for commercial project orders ranges between 15 to 25 business days depending on profile powder coating finishes (RAL custom color matching or anodizing) and glass specification. Flexible MOQ structures are available for mixed container shipments or localized commercial trials.
Absolving technical friction is core to our B2B service. Our in-house engineering team provides complete AutoCAD elevation details, structural wind load analysis (according to TS EN 1991-1-4), and anchor point recommendations to facilitate smooth approval by local Turkish project consultants.